Swim Spa RiverPool®
Swim Spa RiverPool®
Free DVD Banner
Yard Deck Sunroom Basement Garage
More On " Planning & Design For My Sentry RiverPool®"
Planning & Design - Electrical Requirements cont.
   
Electrical Recommendations for Standard Equipment
         
   
220 Volts
Controller
1  
Single Phase
(Wall mounted above the power unit and
Power Unit
   
35 amps
activated pneumatically by air button poolside)
5 HP & 7 1/2 Motors
   
3 line, 10 awg for 200 v., 35 amp breaker, 2 hot's 1 ground
   
220 Volts
2
Single Phase
3 Line, 12 awg for 100 v., 30 amp
Electric Heater
30 amps
breaker, 2 hot's, 1 ground

5.5 kw

220 volts, 30 amps
11 kw
220 volts, 60 amps
         
         
3
220 Volts
3 Line, 12 awg for 200 v., 15 amp breaker
Circulating Pump
15 amps
2 hot's, 1 ground
3/4 HP Motor
220 volts, 15 amps
Facts About Humidity
Select A Configuration
Available Sizes
Available Depths
Accessibility To Your Sentry RiverPool®
Electrical Requirements
Electrical Recommendations for Jets, Lights & Cover
         
Controller
Jets Pump
4
220 Volts
On/Off Controller, Air Activated, Button Poolside
2 HP Motor
20 amps
4 Line, 12 awg for 200 v., 15 amp breaker
220 volts, 20 amps
         
         
5
110 Volts
3 Line, 12 awg for 100 v., 15 amp
Optional Low-Voltage Lights
breaker. 1 hot, 1 common, 1 ground
75 watts each
to 12 volt transformer
         
6  
3 line, 12 awg for 110 v., 10 amp
Automatic Cover
   
110 Volt
breaker, 1 hot, 1 common, 1 ground
110 volts, 10 amps
   
10 amps
1/2 HP Motor
Free DVD Banner
< < return to previous page Next page - RiverPool® Gallery > >
 
Our technology keeps the competition a lap behind!
nspilogo.gif
Spas |
apsplogo.jpg
©1971-2008 Sentry Pool, Inc.
All Rights Reserved
1529 46th Avenue
Moline, IL. 61265
309-797-9721
Call Toll Free 800-443-8625
RiverPool® is a registered trade mark of Sentry Pool, Inc.
03072008